We Have New Edwards E2M40 series two stage oil sealed rotary vane vacuum pumps are renowned for their high ultimate vacuum, rapid pumping speeds. Edwards E2M40FX Vacuum Pump A E2M40 FX, Edwards E2M40 pump PFPE Dual Stage Rotary Vane Pump, ISO40 Inlet Flange, NW25 Outlet. Find great deals for Edwards E2M40 Rotary Vane Vacuum Pump 40 Two Stage. Shop with confidence on eBay!.

Author: Bagul Dairr
Country: Singapore
Language: English (Spanish)
Genre: Art
Published (Last): 5 February 2012
Pages: 245
PDF File Size: 19.25 Mb
ePub File Size: 7.88 Mb
ISBN: 258-2-11522-586-5
Downloads: 13895
Price: Free* [*Free Regsitration Required]
Uploader: Yozshugor

A comprehensive range of accessories is available to allow use on the widest variety of vacuum applications. Reliable system protection devices Every E2M40 pump has protection devices to prevent oil and air suck-back into the vacuum system if the pump stops while under vacuum. ITO Catchpots — installed at the pump inlet to prevent liquids from accumulating in the pump oil and damaging the pump and its performance.

The valve is used to introduce a suitable gas into the stator during the compression stage: All EM pumps are constructed with internal dowels, which reduce the need for skilled setting of tolerances, when the pump is dismantled.

This oil lubrication system means that the level of oil in the reservoir is less critical than with other pump designs. A special feature of the E2M40 is the central vacuum inlet which enables you to fit a mechanical booster pump with a minimum overhang, to create compact combination pumping systems.

Edwards E2M40 Pump

Max water vapour pumping rate. These direct drive rotary vane pumps are inherently compact and vibration free, and with their finger-proof fan and coupling housings they offer excellent operator protection.

Oil supplied with the pump Azide Compatible – AZ Similar to hydrocarbon pumps but with copper and brass parts replaced with other suitable materials such as stainless steel. E2m0 gas ballast partial pressure.

When you use gas ballast on some of the pumps, you must use a solenoid operated gas ballast control valve to prevent air suck-back. Trillium offers a full range of accessories to enhance the operation of your current equipment, but also for purchase with new and refurbished systems. Accessories Trillium offers a full range of accessories to enhance the operation of your current equipment, but s2m40 for purchase with new and refurbished systems.

  ABSES PERIANAL ADALAH PDF

Common versions of the E2M40 are as follows: Buy in bulk and save. Supplied with Ultragrade 70 Oil. A full length, easily visible oil level sight glass allows you to conveniently monitor the oil level.

MF Outlet Mist Filters — capture exhaust oil mists keeping them out of the exhaust system. Without gas ballast total pressure. The pumps are designed so that all key components are easily accessible.

We promise to never spam you, and just use your email address to identify you as a valid customer. FEATURES AND BENEFITS of the Edwards E2M40 Advanced pressurised oil circuit to give effective edwarda even under high gas loads When the pump is switched off, the spring loaded distributor valve provides oil and air suck-back protection Gas Ballast control to assist in handling high water vapour loads Industrial roller bearings on drive shaft for edwsrds reliability and long, trouble free life Full height oil sight glass for easy checking of oil level and condition Easy change oil filter, with oil filter condition gauge on larger models Central inlet port to allow easy mounting of mechanical booster pump if required Easy to maintain, with convenient service kits and international customer support.

When you use gas ballast on some of the pumps, you must use a solenoid operated gas ballast control valve to prevent air suck-back.

Edwards E2M40 Vacuum Pump- Two Stage Rotary Vane Pump 30 CFM

This product hasn’t received any reviews yet. Supplied with Ultragrade oil. The exhaust valve seals and oil distributor seals are exposed after the top cover is removed. A variety of protection devices are used, depending on the pump size and cost, but emphasis is always placed on reliability and simplicity.

The valve is used to introduce a suitable gas into the stator during the compression stage: ITC Inlet Chemical Traps — installed at the pump inlet to prevent aggressive vapors from accumulating in the pump oil and damaging the pump and its performance. Technical Data Displacement 50Hz For applications requiring inert fluids e.

The exhaust valve seals and oil distributor seals are exposed after the top cover is removed. Technical Documents Manuals Contact Us. Write your review here: Eewards Newsletter Your First Name: Therefore, the use of gas ballast reduces oil degradation and pump corrosion.

  ABGYMNIC MANUAL PDF

E2M40 HC IE3 ASIA 50/60HZ 200V 50/60HZ, 380V 60HZ

Max inlet pressure for water vapour. The E2M40 is commonly configured for the integration of a mechanical blower, such as the Edwards EH, which will greatly increase pumping speed. See 5 more pictures. Pumping Systems The E2M40 pumps, with suitable accessories, can partner a variety of other types of pump in vacuum systems for industry and for research. ITF Inlet Dust Filters — installed at the pump inlet to prevent dust particles from accumulating in the pump oil and damaging the pump and its performance.

Overview Edwards E2M series two stage oil sealed rotary vane vacuum pumps are renowned for their high ultimate vacuum, rapid pumping speeds, quiet operation and ability to handle water vapour.

A special feature of the E2M40 is the central vacuum inlet which enables you to fit a mechanical booster pump with a minimum overhang, to create compact combination pumping systems.

The pumps are designed so that all key components are easily accessible. The Edwards E2M40 is a dual stage rotary vane pump commonly used in a wide range of vacuum related industries.

Be sure to inquire about the recommended accessories to enable the most effective operation of your existing and future equipment. This oil lubrication system means that the level of oil in the reservoir is less critical than with other pump designs.

A wide range of accessories to match your application needs The pumps and accessories can be supplied either as individual components or as fully systemised, factory-tested combinations.

Positive Pressure Oil Lubrication The E2M40 pumps incorporate a well proven positive pressure oil lubrication system which as been developed by Edwards to ensure correct lubrication in all duty modes and particularly to prevent oil starvation with high gas loads. Trillium specializes in helping customers using vacuum, closed loop helium, temperature control and gas abatement systems. About Trillium US Trillium specializes in helping customers using vacuum, closed loop helium, temperature control and gas abatement systems.