Buy DIN EN ISO PAINTS AND VARNISHES – DETERMINATION OF RESISTANCE TO NEUTRAL SALT SPRAY (FOG) from SAI. DIN EN ISO Paints and varnishes – Determination of resistance to neutral salt spray (fog) (ISO ); German version EN ISO Draft standard [WITHDRAWN] DIN ISO – Draft. Paints and varnishes – Determination of resistance to neutral salt spray (fog) (ISO.

Author: Arall Kagam
Country: Jamaica
Language: English (Spanish)
Genre: Video
Published (Last): 14 March 2013
Pages: 104
PDF File Size: 9.59 Mb
ePub File Size: 19.82 Mb
ISBN: 245-2-24275-181-8
Downloads: 5892
Price: Free* [*Free Regsitration Required]
Uploader: Saran

The test cabinet shall be filled with dummy specimens of inert materials, such as plastic or glass, during the verification procedure. After cleaning, rinse the reference specimens with fresh solvent, then dry them.

Sample Requirements In order to obtain a total test area of 0.

Corrosion resistance

The support for the reference specimens shall be made of, or coated with, inert materials such as plastic, and shall be placed at the same level as the test specimens. Resistance to Salt Spray. D gives supplementary information needed for testing test panels with organic coatings. It is also designed to reproduce the degradation of non-metallic materials by salt. We can test different size samples if required with maximum dimensions of x x mm If you wish, we can prepare the test panels.

Adjust the pH using the procedures described in 3.

Equivalence between ASTM B-117 vs. ISO 9227 NSS

Recommended periods of exposure are 2 h, 6 h, 24 h, 48 h, 96 h, h, h, h, h and 1 h. It is especially useful for testing decorative coatings of copper? Baffles may be used to prevent direct impact of the spray on the test specimens, and the use of adjustable baffles is helpful in obtaining uniform distribution of the spray within the cabinet. C normative Preparation of panels with organic coatings for testing C.

DowDuPont merger successfully completed 6th September Read more. Assessment of degree of flaking DIN EN ISOPaints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 6: Before they are examined, carefully remove the residues of spray solution from their surfaces.

Check the pH using electrometric measurement or in routine checks, with a short-range pH paper, which can be read in increments or 0,3 pH units or less. Such details are provided in the appropriate product specifications.

  CATALOGO CILINDROS HIDRAULICOS PARKER PDF

Any ISO standard is available for this Testing? The diin involves mounting the test panels in a chamber into which is introduced an aqueous solution of salts in the form of a fine aerosol. After each stripping, thoroughly clean the reference specimens at ambient temperature with water, then with ethanol, followed by drying.

The information required should preferably be agreed between the interested parties and may be derived, in part or totally, from an international or national standard or other document related to the system under test.

Sample Requirements The requirement is the same for all three tests. The ej of the reference test specimens may be protected by the adhesive tape as well. The size and shape of the cabinet shall be such that the collection rate of solution in the cabinet is within the limits specified idn Table 2, measured as specified in 8. I’ll really appreciate your help The cabinet shall be rin only for brief visual inspections of the test specimens in position and for replenishing the salt solution in the reservoir, if such replenishment cannot be carried out from outside the cabinet.

From beautiful Pine Beach New Jersey: The substrate should be one that is appropriate to the type of coating being tested.

The appropriate temperature depends on the pressure used and on the type of atomizer nozzle and shall be adjusted so that the rate of collection of spray in the cabinet and the concentration of the collected spray are kept within the specified limits see? The scribe mark s shall be parallel to the longer edge of the test panel, unless otherwise dkn. Is it possible to reduce test duration by some accelerated Testing?

The upper parts of the cabinet shall be designed so that drops of sprayed solution formed on its surface do not fall on the specimens being tested. However, for a new examination or for tests with a total duration exceeding 96 h, location permutation of specimens is permitted The specimens may be placed at different levels within the cabinet, as long eh the solution does not drip from specimens or their supports at one level onto other specimens placed below. As a complement to reference-metal specimens made of steel, high-purity zinc reference-metal specimens may also be exposed in the tests, to determine the corrosivity against this metal as described in Annex B.

  HD74LS02P DATASHEET PDF

Resistance to Sulphur Dioxide. Also, the performance of different materials, during the test should not be taken as a direct guide to the corrosion resistance of these materials in service. They shall be placed so that only mist, and not liquid falling from specimens or from parts of the cabinet, is collected. Avenue Marnix 17, B Brussels?

The upper parts of the cabinet shall be designed so that drops of sprayed solution formed on its surface do not fall on the specimens being tested. The edges of the reference test specimens may be protected by the adhesive tape as dinn 5. Sample Requirements Ideally x 75 mm coated burnished steel panels not more that 5 mm thick, although we can accommodate a limited number of x mm panels provided they are less than 5 mm thick. The support for the reference specimens shall be made of, or coated with, inert materials such as plastics.

Equivalence between ASTM B vs. ISO NSS

Cut these reference specimens from cold? The scratch shall have either parallel sides or an upwards-broadening cross-section which dkn a width of 0,2 mm to 1,0 mm of the metallic substrate, unless otherwise agreed. The test duration is 24? Hi Sergio, ASTM B does not address corrosion behavior of test specimens, but describes the parameters for conducting a salt spray test.

The method is designed to reproduce the corrosive effect of salt on metals where the mechanism is primarily electrochemical. Welcome to new Member Olin Epoxy! In practice this means that the test object must be capable of fitting inside a cube with mm sides.

Sample Requirements We require 3 coated panels x mm. Remove the corrosion products by mechanical and chemical cleaning as described in ISO We have a customer, that we supply some zinc electroplated mechanical components to. Test specimens of types different from the reference specimens shall not be placed in the test chamber during the verification procedure.